Cutaway view of a passenger train - a carriage interior where Paged FR plywood is used

Fire-retardant plywood for rail transport

Railways

Fire-retardant solutions compliant with EN 45545-2

  • HL3the highest fire hazard level – floors (R10)
  • HL2walls, ceilings and fittings (R1, R2, R7)
  • EN 45545-2compliance confirmed by fire test reports
  • 5FR plywood products for floors, fit-out and interior soundproofing

Paged fire-retardant plywood for railway applications meets the highest requirements for the fire hazard level according to EN 45545-2.

Paged BirchPly FR - fire-retardant hardwood plywood for railway applications

EN 45545-2 sets out the requirements for the reaction to fire of materials and products used in rail vehicles. Vehicles are classified according to three fire hazard levels – from HL1, the lowest, to HL3, the highest. The level depends on the train’s route, that is, how quickly a passenger can reach a place of safety in the event of fire, and on the type of train, e.g. a sleeping car or a double-decker train.

The requirements for the material itself depend on where it is located in the vehicle – the standard describes 26 such groups, from R1 to R26. Our plywood achieves HL3 under requirement R10, i.e. in flooring systems, and HL2 under requirements R1, R2 and R7, which cover walls, ceilings and interior fittings.

  • EN 45545-2fire safety requirements for rail vehicles
  • HL3R10flooring systems
  • HL2R1walls, doors, ceilings, storage compartments, luggage compartments
  • HL2R2R7small interior trim and fittings up to 0.2 m², sleeper seat and bed base panels, air ducts
Cutaway view of a passenger train against a mountain backdrop1Floor – R102Interior – R1, R2, R7

Product classification

Compliance with fire safety regulations – in accordance with the requirements set out in standard EN 45545-2.

Drawing: plywood in a carriage flooring system1

Flooring systems

R10 requirements

Fire hazard level HL3

Products meeting the requirements:

Drawing: carriage interior with zones R1, R2 and R7 marked2

Walls, ceilings and fittings

R1 / R2 / R7 requirements

Fire hazard level HL2

  • R1ceiling, door and wall panels, luggage storage areas
  • R2small interior trim and fitting features with up to 0.2 m² of exposed surface area, e.g. tables
  • R7sleeper seat and bed base panels; air ducts

Products meeting the requirements:

Maximum safety. Paged fire-retardant plywood for railway applications meets the highest requirements for the fire hazard level. Depending on the classification, it achieves HL3 under R10, and HL2 under R1, R2 and R7. It can be used, for example, in sleeping cars and in rail vehicles operating in tunnels without emergency evacuation facilities.

We respond to your needs

High strength

Hardwood plywood with high mechanical strength carries the loads of floors, walls and fit-out elements.

Compliance with standards and certification

Fire hazard level HL3 (R10) and HL2 (R1, R2, R7) according to EN 45545-2, confirmed by fire test reports.

Greater passenger comfort and safety

Paged Phon FR dampens vehicle noise and vibration, while the anti-slip films of Mesh FR and Hexa FR reduce the risk of slipping.

Wear resistance

Film-faced surfaces are resistant to abrasion and moisture, so they perform well on floors with heavy traffic.

Interior of a passenger carriage with exposed plywood in the floor and fit-out

Applications

Flooring systems – requirement R10, level HL3

The carriage floor and other horizontal upward-facing surfaces are subject to requirement R10. All our railway plywood achieves the highest level, HL3, under it, so you can match the solution to the zone of the vehicle.

  • Paged Mesh FR and Hexa FR – anti-slip film for the safety of passengers and staff
  • Wear resistance and strength in heavily loaded areas
  • Paged Master Form FR – phenolic film protecting against moisture, birch or beech version
  • Paged Phon FR – layer damping noise and vibration, sound insulation up to 33 dB
  • Paged BirchPly FR – unfaced plywood to which a finish covering can be applied

Sound insulationPaged Phon FR

Paged Phon FR is a composite panel made of hardwood plywood with a core of a special rubber sound-damping layer. It provides sound insulation of up to 33 dB, compared with approx. 27 dB for the other FR plywood products. It is also available in a version with phenolic film.

  • High fire safety standard HL3 (R10)
  • Protection of the structure through vibration damping
  • Sound insulation that ensures passenger comfort
  • Durability and resistance to mechanical loads
Paged Phon FR - composite panel

Walls, doors and ceilings – requirement R1, level HL2Paged BirchPly FR

Requirement R1 covers vertical interior surfaces such as walls and doors, downward-facing surfaces including ceiling panels and storage compartments, and luggage compartments. Paged BirchPly FR meets level HL2 under it, as well as under requirements R2 and R7, so a single material can be used for walls, doors, ceilings, flaps and storage compartments.

  • Strength at a relatively low weight – the plywood can serve as a structural and fit-out element
  • Dimensional stability and consistent parameters, essential for series production of vehicle components
  • Easy, precise machining to suit the specific geometry and requirements of the project
  • Freedom of finish – the surface can be further finished and matched to the interior design
Paged BirchPly FR - fire-retardant hardwood plywood panels

Interior and fittings – requirements R1, R2 and R7, level HL2More functions from a single material

Small interior trim and fittings (R2), luggage compartments (R1), sleeper seat and bed base panels and air ducts (R7) – we match FR solutions to the place of use and the required hazard level, including in the most demanding vehicles.

  • Material engineered for the application – panel construction, thickness, surface and properties selected for the specific component
  • Fewer materials and simpler integration – a single panel can combine a structural function, fire protection, a usable surface or vibration damping
  • Passenger comfort – acoustic solutions limit the transmission of sound and vibration
  • Paged LabTech support – testing, validation and development of custom configurations from concept to implementation
How to choose plywood for your project

The products differ in more than their fire classification. The film-faced surfaces of Mesh FR and Hexa FR protect against moisture, but are not suitable for applying a covering. A covering can be applied to BirchPly FR, but it has no moisture protection. Phon FR and Master Form FR combine both features: the film-faced side is moisture-resistant, and a covering can be applied to the impregnated side.

Swipe the table sideways to see all products.

Feature Paged Phon FR - panels and edge with the sound-damping layerPaged Phon FR Paged BirchPly FR - panels and birch surfacePaged BirchPly FR Paged Mesh FR - panels and mesh texturePaged Hexa FR - panels and hexagonal texturePaged Mesh FR / Hexa FR Paged Master Form FR - panels and smooth filmPaged Master Form FR
Fire hazard level and R requirements HL3 (R10) HL3 (R10)HL2 (R1, R2, R7) HL3 (R10) HL3 (R10)
Density 920-1250 kg/m³beech wood920-1150 kg/m³hardwood 640-760 kg/m³R10720-880 kg/m³R1, R2, R7 640-760 kg/m³ 720-880 kg/m³beech wood640-760 kg/m³hardwood
Sound insulation up to 33 dB approx. 27 dB approx. 27 dB approx. 27 dB
Option to apply a covering NOfilm-faced sideYESimpregnated side YES NO NOfilm-faced sideYESimpregnated side
Mechanical strength 8 8 9 10beech wood9hardwood
Moisture-proofing YESfilm-faced sideNOimpregnated side NO YES YESfilm-faced sideNOimpregnated side
Dimensional stability 7beech wood8hardwood 8 8 7beech wood8hardwood
Biological durability 9film-faced side8impregnated side 8 9 9film-faced side8impregnated side
Machining precision 10beech wood9hardwood 9 9 10beech wood9hardwood

The numerical ratings compare Paged FR products and come from the presentation “FR products for railways” (2026). Thicknesses and formats can be found in the downloadable product overview and on the product pages.

Standards and test reports

Fire safety requirements for rail vehicles are set out in EN 45545-2. The compliance of Paged plywood with its requirements is confirmed by fire tests carried out in an accredited laboratory.

Standard

EN 45545-2

Part 2: Requirements for fire behaviour of materials and components.

  • Scopereaction to fire of materials and products used in rail vehicles
  • Hazard levelsHL1 – the lowest, HL2 and HL3 – the highest; they depend on the route and type of train
  • Testingtest methods, test conditions and requirements for each hazard level
First page of the Sychta Laboratorium fire test report no. SL/Z-345/EN45545-R10/447/2020

Fire test report

Requirement R10 for levels HL1, HL2 and HL3

Sychta Laboratorium – Materials Flammability Testing Laboratory, PCA accreditation AB 1501.

  • Materialfilm-faced FR hardwood plywood, thickness from 9 mm
  • Test methodsPN-EN ISO 5659-2 (optical density of smoke), PN-EN ISO 9239-1 (reaction to fire of floorings)
  • Resultmeets the R10 requirements of PN-EN 45545-2:2013+A1:2015 for HL1, HL2 and HL3
  • Reportno. SL/Z-345/EN45545-R10/447/2020 of 3 July 2020
Video
Contact

If you are interested in working with us, fill in the form below.

Customer Service

+48 693 909 030